FCQHG71FVEB / RZQG71L7V1B FCQHG71FVEB / RZQG71L7Y1B9 FCQHG100FVEB / RZQG100L7Y1B FCQHG100FVEB / RZQG100L7V1B FCQHG125FVEB / RZQG125L7V1B FCQHG125FVEB / RZQG125L7Y1B
Poff (uitgeschakeld) W 0.0 0.0 0.0 0.0 0.0 0.0
Koelen Psb (koeling in stand-by) W 7.0 7.0 9.0 9.0 9.0 9.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25
Seizoensrendement (volgens EN14825) Koelen Pdesign kW 6.80 6.80 9.50 9.50 12.00 12.00
    Jaarlijks energieverbruik kWu 389.525 389.525 535.427 535.427 700 700
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.11 6.11 6.21 6.21 6.00 6.00
    D voorwaarden (20℃ - 27/19) Pdc kW 4.33 4.33 6.05 6.05 5.73 5.73
      Opgenomen vermogen kW 0.45 0.45 0.61 0.61 0.59 0.59
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.62 9.53 9.88 9.86 9.68 9.78
    C voorwaarden (25℃ - 27/19) Opgenomen vermogen kW 0.58 0.59 0.76 0.76 0.81 0.80
      Pdc kW 4.12 4.12 5.79 5.79 6.00 6.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.08 7.02 7.63 7.59 7.44 7.49
    A voorwaarden (35°C - 27/19) Opgenomen vermogen kW 1.66 1.66 2.15 2.15 3.05 3.05
      Pdc kW 6.80 6.80 9.50 9.50 12.00 12.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.09 4.09 4.42 4.42 3.94 3.94
    B voorwaarden (30℃ - 27/19) Pdc kW 5.01 5.01 7.00 7.00 8.84 8.84
      Opgenomen vermogen kW 0.82 0.80 1.19 1.18 1.84 1.87
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.12 6.23 5.87 5.92 4.82 4.74
  Verwarmen (gematigd klimaat) Jaarlijks energieverbruik kWu 2,545.455 2,545.455 3,680 3,680 5,085 5,085
    Pdesign kW 7.60 7.60 11.30 11.30 14.13 14.13
    Min. vermogen backupVerwarmen bij ontwerpvoorwdn kW 0.89 0.88 1.61 1.61 1.77 1.79
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+ A+ A+ A+ A A
    TBivalent Pdh (Verwarmensvermogen) kW 6.72 6.72 10.00 10.00 12.50 12.50
      Opgenomen vermogen kW 2.16 2.24 2.70 2.69 4.47 4.48
      Tbiv (bivalente temperatuur) °C -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.11 3.00 3.71 3.72 2.80 2.79
    C voorwaarden (7℃) Pdh (Verwarmensvermogen) kW 2.93 2.93 4.17 4.16 4.89 4.89
      Opgenomen vermogen kW 0.47 0.46 0.71 0.70 5.71 5.70
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.26 6.40 5.91 5.92 0.86 0.86
    TOL TOL (bedrijfstemperatuur) °C -15 -15 -15 -15 -15 -15
      Pdh (beschikbaar Verwarmensvermogen) kW 6.69 6.71 9.17 9.18 12.12 12.07
      Opgenomen vermogen kW 2.88 2.96 3.32 3.34 5.69 5.65
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.32 2.27 2.76 2.75 2.13 2.14
    A voorwaarden (-7°C) Pdh (Verwarmensvermogen) kW 6.72 6.72 10.00 10.00 12.50 12.50
      Opgenomen vermogen kW 2.16 2.24 2.70 2.69 4.47 4.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.11 3.00 3.71 3.72 2.80 2.79
    D voorwaarden (12℃) Pdh (Verwarmensvermogen) kW 3.33 3.33 4.77 4.76 5.40 5.40
      Opgenomen vermogen kW 0.46 0.44 0.69 0.68 0.80 0.80
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.32 7.65 6.93 6.95 6.78 6.76
    B voorwaarden (2°C) Opgenomen vermogen kW 1.24 1.24 1.73 1.73 2.20 2.20
      Pdh (Verwarmensvermogen) kW 4.70 4.70 6.45 6.43 7.61 7.61
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.79 3.78 3.73 3.72 3.45 3.46
Totale koelcapaciteit Nom. kW 6.8 6.8 9.5 9.5 12.0 12.0
Pck (verwarming krukkast) W 0.0 0.0 0.0 0.0 0.0 0.0
Nominaal energierendement Jaarlijks energieverbruik kWu 830 (0.000) 830 (0.000) 1,075 (0.000) 1,075 (0.000) 1,500 (0.000) 1,500 (0.000)
  Richtlijn Energielabels Verwarming A A A A A A
  Nominal efficiency-=-Cop 4.09 4.09 4.42 4.42 4.00 4.00
Verwarmen Psb (verwarming in stand-by) W 14.0 14.0 16.0 16.0 16.0 16.0
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25
Totale verwarmingscapaciteit Nom. kW 7.5 7.5 10.8 10.8 13.5 13.5
Pto (Thermostat off) W 49.0 49.0 109.0 109.0 120.0 120.0
Koud seizoen inbegrepen Ja Ja Ja Ja Ja Ja
Opmerkingen EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU
  Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting