FBQ100C8VEB / RZQG100L9V1B FBQ71C8VEB / RZQG71L9V1B FBQ125C8VEB / RZQG125L9V1B
Poff (uitgeschakeld) W 0.0 0.0 0.0
Koelen Psb (koeling in stand-by) W 9.0 7.0 9.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Seizoensrendement (volgens EN14825) Koelen Pdesign kW 9.50 6.80 12.00
    Jaarlijks energieverbruik kWu 574 390 723
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.80 5.61, 6.11 5.81
    D voorwaarden (20℃ - 27/19) Pdc kW 5.93 4.06 5.74
      Opgenomen vermogen kW 0.61 0.40 0.67
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.77 10.18 8.66
    C voorwaarden (25℃ - 27/19) Opgenomen vermogen kW 0.77 0.50 0.87
      Pdc kW 5.72 3.92 6.01
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.52 7.89 6.92
    A voorwaarden (35°C - 27/19) Opgenomen vermogen kW 2.45 1.95 3.15
      Pdc kW 9.50 6.80 12.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.89 3.50 3.81
    B voorwaarden (30℃ - 27/19) Pdc kW 7.20 5.01 8.84
      Opgenomen vermogen kW 1.73 1.05 1.93
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.17 4.78 4.59
  Verwarmen (gematigd klimaat) Jaarlijks energieverbruik kWu 3,432 2,095 4,227
    Pdesign kW 11.30 6.00 12.71
    Min. vermogen backupVerwarmen bij ontwerpvoorwdn kW 1.74 0.28 1.30
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A++ A+ A+
    TBivalent Pdh (Verwarmensvermogen) kW 10.00 5.31 11.24
      Opgenomen vermogen kW 2.88 1.89 4.14
      Tbiv (bivalente temperatuur) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.48 2.81 2.72
    C voorwaarden (7℃) Pdh (Verwarmensvermogen) kW 4.06 2.85 4.73
      Opgenomen vermogen kW 0.63 0.60 0.76
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.48 4.76 6.26
    TOL TOL (bedrijfstemperatuur) °C -15 -15 -15
      Pdh (beschikbaar Verwarmensvermogen) kW 8.82 6.38 11.67
      Opgenomen vermogen kW 3.41 3.23 5.90
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.59 1.98 1.98
    A voorwaarden (-7°C) Pdh (Verwarmensvermogen) kW 10.00 5.31 11.24
      Opgenomen vermogen kW 2.88 1.89 4.14
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.48 2.81 2.72
    D voorwaarden (12℃) Pdh (Verwarmensvermogen) kW 4.65 3.24 5.39
      Opgenomen vermogen kW 0.62 0.60 0.75
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.56 5.48 7.28
    B voorwaarden (2°C) Opgenomen vermogen kW 1.49 0.76 1.87
      Pdh (Verwarmensvermogen) kW 6.12 3.23 7.18
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.13 4.26 3.86
Totale koelcapaciteit Nom. kW 9.5 6.8 12.0
Pck (verwarming krukkast) W 0.0 0.0 0.0
Nominaal energierendement Jaarlijks energieverbruik kWu 1,220 (0.000) 970 (0.000) 1,575 (0.000)
  Richtlijn Energielabels Verwarming A A A
  Nominal efficiency-=-Cop 3.89 3.50 3.81
Verwarmen Psb (verwarming in stand-by) W 9.0 7.0 9.0
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Totale verwarmingscapaciteit Nom. kW 10.8 7.5 13.5
Pto (Thermostat off) W 9.0 7.0 9.0
Koud seizoen inbegrepen Ja Ja Ja
Opmerkingen EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU
  Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting