Tabel met technische gegevens voor FCAG-A / RZASG-MV1

FCAG71AVEB / RZASG71M2V1B FCAG35AVEB / FCAG35AVEB / RZASG71M2V1B FCAG100AVEB / RZASG100M7V1B FCAG35AVEB / FCAG35AVEB / FCAG35AVEB / RZASG100M7V1B FCAG50AVEB / FCAG50AVEB / RZASG100M7V1B FCAG125AVEB / RZASG125M7V1B FCAG35AVEB / FCAG35AVEB / FCAG35AVEB / FCAG35AVEB / RZASG125M7V1B FCAG140AVEB / RZASG140M7V1B FCAG35AVEB / FCAG35AVEB / FCAG35AVEB / FCAG35AVEB / RZASG140M7V1B
Outdoor unit RZASG71M2V1B RZASG71M2V1B RZASG100M7V1B RZASG100M7V1B RZASG100M7V1B RZASG125M7V1B RZASG125M7V1B RZASG140M7V1B RZASG140M7V1B
Totale koelcapaciteit Nom. kW 6.80 6.80 9.5 9.50 9.50 12.1 12.1 13.4 13.4
Totale verwarmingscapaciteit Nom. kW 7.50 7.50 10.8 10.8 10.8 13.5 13.5 15.5 15.5
Koeling Koeling-=-Energieklasse   A++ A++ A++ A++ A++
  Vermogen Pdesign kW 6.80 6.80 9.5 9.50 9.50 12.1 12.1 13.4 13.4
  SEER   6.47 7.05 6.5 7.22 6.80 5.76 9.47 6.53 11.6
  Jaarlijks energieverbruik kWu/a 368 338 507 461 489 1261 767 1231 694
Verwarming (gematigd klimaat) Energieklasse   A A+ A+ A+ A
  Vermogen Pdesign kW 4.50 4.50 6.0 6.00 6.00 6.00 6.00 7.80 7.80
  SCOP/A   4.00 4.31 4.2 4.07 3.90 4.05 4.65 4.31 5.49
  Jaarlijks energieverbruik kWu/a 1575 1462 2016 2064 2154 2074 1807 2534 1989
Opmerkingen (1) - Koelen: T2: binnentemp. 26,6°C DB, 19,4°C NB, buitentemp. 48°CDB [Btu/u/W] (1) - Koelen: T2: binnentemp. 26,6°C DB, 19,4°C NB, buitentemp. 48°CDB [Btu/u/W] (1) - De nominale koelcapaciteiten zijn gebaseerd op: binnentemperatuur: 27°CDB/19°CNB, buitentemp.: 35°CDB; equivalente koelmiddelleidinglengte: 5m, hoogteverschil: 0 m. (1) - De nominale koelcapaciteiten zijn gebaseerd op: binnentemperatuur: 27°CDB/19°CNB, buitentemp.: 35°CDB; equivalente koelmiddelleidinglengte: 5m, hoogteverschil: 0 m. (1) - De nominale koelcapaciteiten zijn gebaseerd op: binnentemperatuur: 27°CDB/19°CNB, buitentemp.: 35°CDB; equivalente koelmiddelleidinglengte: 5m, hoogteverschil: 0 m. (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.