EWAA004D2V3P-H |
EWAA006D2V3P-H |
EWAA008D2V3P-H |
EWAA011DAV3P-H- |
EWAA014DAV3P-H- |
EWAA016DAV3P-H- |
Totale koelcapaciteit
|
Nom.
|
kW
|
4.86 (1), 4.52 (2)
|
5.83 (1), 5.09 (2)
|
6.18 (1), 5.44 (2)
|
11.6 (1), 11.5 (2)
|
12.8 (1), 12.7 (2)
|
14.0 (1), 15.3 (2)
|
Capaciteitsregeling
|
Methode
|
|
Variabel (omvormer)
|
Variabel (omvormer)
|
Variabel (omvormer)
|
Variabel (omvormer)
|
Variabel (omvormer)
|
Variabel (omvormer)
|
Opgenomen vermogen
|
Koelen
|
Nom.
|
kW
|
0.820 (1), 1.36 (2)
|
1.08 (1), 1.55 (2)
|
1.19 (1), 1.73 (2)
|
3.56 (1), 2.17 (2)
|
4.06 (1), 2.51 (2)
|
4.58 (1), 3.24 (2)
|
EER
|
5.91 (1), 3.32 (2)
|
5.40 (1), 3.28 (2)
|
5.19 (1), 3.14 (2)
|
3.26 (1), 5.31 (2)
|
3.16 (1), 5.04 (2)
|
3.06 (1), 4.74 (2)
|
SEER
|
|
|
|
5.79 (5)
|
5.71 (5)
|
5.59 (5)
|
Afmetingen
|
Unit
|
Diepte
|
mm
|
362
|
362
|
362
|
460
|
460
|
460
|
|
|
Hoogte
|
mm
|
770
|
770
|
770
|
870
|
870
|
870
|
|
|
Breedte
|
mm
|
1250
|
1250
|
1250
|
1380
|
1380
|
1380
|
Gewicht
|
Unit
|
kg
|
88
|
88
|
88
|
147
|
147
|
147
|
Behuizing
|
Kleur
|
|
Ivoorwit
|
Ivoorwit
|
Ivoorwit
|
Ivoorwit
|
Ivoorwit
|
Ivoorwit
|
|
Materiaal
|
|
Verzinkt plaatstaal
|
Verzinkt plaatstaal
|
Verzinkt plaatstaal
|
Gegalvaniseerde staalplaat met polyesterlak
|
Gegalvaniseerde staalplaat met polyesterlak
|
Gegalvaniseerde staalplaat met polyesterlak
|
Luchtgekoelde warmtewisselaar
|
Type
|
|
|
|
|
Uiterst efficiënte lamel en buistype met integrale nakoeler
|
Uiterst efficiënte lamel en buistype met integrale nakoeler
|
Uiterst efficiënte lamel en buistype met integrale nakoeler
|
Ventilator
|
Aantal
|
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Type
|
|
Schroefventilator
|
Schroefventilator
|
Schroefventilator
|
Schroefventilator
|
Schroefventilator
|
Schroefventilator
|
Ventilatormotor
|
Aandrijving
|
|
|
|
|
Directe aandrijving
|
Directe aandrijving
|
Directe aandrijving
|
Compressor
|
Aantal
|
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Type
|
|
Hermetisch gesloten swingcompressor
|
Hermetisch gesloten swingcompressor
|
Hermetisch gesloten swingcompressor
|
Hermetisch gesloten swing-inverter-compressor
|
Hermetisch gesloten swing-inverter-compressor
|
Hermetisch gesloten swing-inverter-compressor
|
|
Aanloopmethode_
|
|
|
|
|
Invertergestuurd
|
Invertergestuurd
|
Invertergestuurd
|
Werkingsbereik
|
Luchtzijdig
|
Koelen
|
Min.
|
°CDB
|
10 (3)
|
10 (3)
|
10 (3)
|
10
|
10
|
10
|
|
|
|
Max.
|
°CDB
|
43
|
43
|
43
|
43
|
43
|
43
|
Bedrijfsbereik
|
Waterkant
|
Verdamper
|
Min.
|
°CDB
|
5 (3)
|
5 (3)
|
5 (3)
|
5
|
5
|
5
|
|
|
|
Max.
|
°CDB
|
22
|
22
|
22
|
22
|
22
|
22
|
Geluidsvermogenniveau
|
Koelen
|
Geluidsvermogenniveau-=-Koelen-=-Nom.-=-dB(A)
|
dB(A)
|
61
|
62
|
62
|
67.0
|
69.0
|
69.0
|
Geluidsdrukniveau op 1 m
|
Koelen
|
Nom.
|
dB(A)
|
48
|
49
|
50
|
47.7
|
50.8
|
51.0
|
Koelmiddel
|
Type
|
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
|
GWP
|
|
675
|
675
|
675
|
675.0
|
675.0
|
675.0
|
|
Vulling
|
kg
|
1.35
|
1.35
|
1.35
|
Koudemiddel
|
Circuits
|
Aantal
|
|
|
|
|
1
|
1
|
1
|
Voeding
|
Fase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
Spanningsvorm
|
Frequentie
|
Hz
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Spanning
|
V
|
230 +/-10%
|
230 +/-10%
|
230 +/-10%
|
230
|
230
|
230
|
|
Spanningsbereik
|
Min.
|
%
|
|
|
|
-10
|
-10
|
-10
|
|
|
Max.
|
%
|
|
|
|
10
|
10
|
10
|
Unit
|
Bedrijfsstroom
|
Max.
|
A
|
|
|
|
30.8
|
30.8
|
30.8
|
Opmerkingen
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(1) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(1) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(2) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(2) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
|
(3) - Raadpleeg de werkbereik-tekening voor meer informatie
|
(3) - Raadpleeg de werkbereik-tekening voor meer informatie
|
(3) - Raadpleeg de werkbereik-tekening voor meer informatie
|
(3) - Overeenkomstig EN14825
|
(3) - Overeenkomstig EN14825
|
(3) - Overeenkomstig EN14825
|
|
|
|
|
(4) - Afhankelijk van de bedrijfsmodus, zie installatiehandleiding
|
(4) - Afhankelijk van de bedrijfsmodus, zie installatiehandleiding
|
(4) - Afhankelijk van de bedrijfsmodus, zie installatiehandleiding
|