Tabel met technische gegevens voor ETSXB12E / EPRA08-12EV

ETSXB12P50EF / EPRA08EAV3 ETSXB12P30EF / EPRA08EAV3 ETSXB12P50EF / EPRA10EAV3 ETSXB12P30EF / EPRA10EAV3 ETSXB12P50EF / EPRA12EAV3 ETSXB12P30EF / EPRA12EAV3
Binnendeel ETSXB12P50EF ETSXB12P30EF ETSXB12P50EF ETSXB12P30EF ETSXB12P50EF ETSXB12P30EF
Totale verwarmingscapaciteit Nom. kW 6.17 (1) 6.17 (1) 6.17 (1) 6.17 (1) 6.17 (1) 6.17 (1)
Totale koelcapaciteit Nom. kW 6.81 (2) 6.81 (2) 7.97 (2) 7.97 (2) 8.62 (2) 8.62 (2)
Opgenomen vermogen Verwarmen Nom. kW 1.25 (1) 1.25 (1) 1.25 (1) 1.25 (1) 1.25 (1) 1.25 (1)
  Koelen Opgenomen vermogen-=-Koelen-=-Nom.-=-kW (2) kW 2.15 (2) 2.15 (2) 2.66 (2) 2.66 (2) 2.96 (2) 2.96 (2)
COP 4.92 (3) 4.92 (3) 4.92 (3) 4.92 (3) 4.92 (3) 4.92 (3)
EER 3.17 (2) 3.17 (2) 3 3 2.91 (2) 2.91 (2)
Verwarming van sanitair warm water Algemeen Aangegevens belastingprofiel   XL L XL L XL L
  Gematigd klimaat Energierendementsklasse waterverwarming   A+ A+ A+ A+ A+ A+
Verwarming Wateruitlaat gematigd klimaat 55°C Algemeen SCOP   3.47 3.47 3.48 3.48 3.48 3.48
      Seizoensefficiëntieklasse verwarming   A++ A++ A++ A++ A++ A++
  Wateruitlaat gematigd klimaat 35°C Algemeen SCOP   4.79 4.79 4.82 4.82 4.82 4.82
      Seizoensefficiëntieklasse verwarming   A+++ A+++ A+++ A+++ A+++ A+++
Opmerkingen (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental