ETSX12P30EF / EPRA08EAW1 |
ETSX12P50EF / EPRA08EAW1 |
ETSX12P30EF / EPRA10EAW1 |
ETSX12P50EF / EPRA10EAW1 |
ETSX12P30EF / EPRA12EAW1 |
ETSX12P50EF / EPRA12EAW1 |
Binnendeel
|
ETSX12P30EF
|
ETSX12P50EF
|
ETSX12P30EF
|
ETSX12P50EF
|
ETSX12P30EF
|
ETSX12P50EF
|
Totale verwarmingscapaciteit
|
Nom.
|
kW
|
6.17 (1)
|
6.17 (1)
|
6.17 (1)
|
6.17 (1)
|
6.17 (1)
|
6.17 (1)
|
Totale koelcapaciteit
|
Nom.
|
kW
|
6.81 (2)
|
6.81 (2)
|
7.97 (2)
|
7.97 (2)
|
8.62 (2)
|
8.62 (2)
|
Opgenomen vermogen
|
Verwarmen
|
Nom.
|
kW
|
1.21 (1)
|
1.21 (1)
|
1.21 (1)
|
1.21 (1)
|
1.21 (1)
|
1.21 (1)
|
|
Koelen
|
Opgenomen vermogen-=-Koelen-=-Nom.-=-kW (2)
|
kW
|
2.08 (2)
|
2.08 (2)
|
2.57 (2)
|
2.57 (2)
|
2.86 (2)
|
2.86 (2)
|
COP
|
5.1
|
5.1
|
5.1
|
5.1
|
5.1
|
5.1
|
EER
|
3.28 (2)
|
3.28 (2)
|
3.1
|
3.1
|
3.01 (2)
|
3.01 (2)
|
Verwarming van sanitair warm water
|
Algemeen
|
Aangegevens belastingprofiel
|
|
L
|
XL
|
L
|
XL
|
L
|
XL
|
|
Gematigd klimaat
|
Energierendementsklasse waterverwarming
|
|
A+
|
A+
|
A+
|
A+
|
A+
|
A+
|
Verwarming
|
Wateruitlaat gematigd klimaat 55°C
|
Algemeen
|
SCOP
|
|
3.59
|
3.59
|
3.6
|
3.6
|
3.6
|
3.6
|
|
|
|
Seizoensefficiëntieklasse verwarming
|
|
A++
|
A++
|
A++
|
A++
|
A++
|
A++
|
|
Wateruitlaat gematigd klimaat 35°C
|
Algemeen
|
SCOP
|
|
4.95
|
4.95
|
4.98
|
4.98
|
4.98
|
4.98
|
|
|
|
Seizoensefficiëntieklasse verwarming
|
|
A+++
|
A+++
|
A+++
|
A+++
|
A+++
|
A+++
|
Opmerkingen
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
|
(3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental
|
(3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental
|
(3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental
|
(3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental
|
(3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental
|
(3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental
|