Tabel met technische gegevens voor ETSX12E / EPRA08-12EW

ETSX12P30EF / EPRA08EAW1 ETSX12P50EF / EPRA08EAW1 ETSX12P30EF / EPRA10EAW1 ETSX12P50EF / EPRA10EAW1 ETSX12P30EF / EPRA12EAW1 ETSX12P50EF / EPRA12EAW1
Binnendeel ETSX12P30EF ETSX12P50EF ETSX12P30EF ETSX12P50EF ETSX12P30EF ETSX12P50EF
Totale verwarmingscapaciteit Nom. kW 6.17 (1) 6.17 (1) 6.17 (1) 6.17 (1) 6.17 (1) 6.17 (1)
Totale koelcapaciteit Nom. kW 6.81 (2) 6.81 (2) 7.97 (2) 7.97 (2) 8.62 (2) 8.62 (2)
Opgenomen vermogen Verwarmen Nom. kW 1.21 (1) 1.21 (1) 1.21 (1) 1.21 (1) 1.21 (1) 1.21 (1)
  Koelen Opgenomen vermogen-=-Koelen-=-Nom.-=-kW (2) kW 2.08 (2) 2.08 (2) 2.57 (2) 2.57 (2) 2.86 (2) 2.86 (2)
COP 5.1 5.1 5.1 5.1 5.1 5.1
EER 3.28 (2) 3.28 (2) 3.1 3.1 3.01 (2) 3.01 (2)
Verwarming van sanitair warm water Algemeen Aangegevens belastingprofiel   L XL L XL L XL
  Gematigd klimaat Energierendementsklasse waterverwarming   A+ A+ A+ A+ A+ A+
Verwarming Wateruitlaat gematigd klimaat 55°C Algemeen SCOP   3.59 3.59 3.6 3.6 3.6 3.6
      Seizoensefficiëntieklasse verwarming   A++ A++ A++ A++ A++ A++
  Wateruitlaat gematigd klimaat 35°C Algemeen SCOP   4.95 4.95 4.98 4.98 4.98 4.98
      Seizoensefficiëntieklasse verwarming   A+++ A+++ A+++ A+++ A+++ A+++
Opmerkingen (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental (3) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental