Tabel met technische gegevens voor EBSX-D / ERLA11-14DV3

EBSX11P30DF / ERLA11D2V3 EBSX11P50DF / ERLA11D2V3 EBSX11P30DF / ERLA11DAV3 EBSX11P50DF / ERLA11DAV3 EBSX16P30DF / ERLA14D2V3 EBSX16P50DF / ERLA14D2V3 EBSX16P30DF / ERLA14DAV3 EBSX16P50DF / ERLA14DAV3
Binnendeel EBSX11P30DF EBSX11P50DF EBSX11P30DF EBSX11P50DF EBSX16P30DF EBSX16P50DF EBSX16P30DF EBSX16P50DF
Totale verwarmingscapaciteit Nom. kW 10.6 (1) 10.6 (1) 10.6 (1) 10.6 (1) 12.0 (1) 12.0 (1) 12.0 (1) 12.0 (1)
Totale koelcapaciteit Nom. kW 11.2 (2) 11.2 (2) 11.2 (2) 11.2 (2) 12.9 (2) 12.9 (2) 12.9 (2) 12.9 (2)
Opgenomen vermogen Verwarmen Nom. kW 2.19 (1) 2.19 (1) 2.19 (1) 2.19 (1) 2.46 (1) 2.46 (1) 2.46 (1) 2.46 (1)
  Koelen Nom. kW 3.47 (2) 3.47 (2) 3.47 (2) 3.47 (2) 4.34 (2) 4.34 (2) 4.34 (2) 4.34 (2)
COP 4.83 (1) 4.83 (1) 4.83 (1) 4.83 (1) 4.87 (1) 4.87 (1) 4.87 (1) 4.87 (1)
EER 3.22 (2) 3.22 (2) 3.22 (2) 3.22 (2) 2.98 (2) 2.98 (2) 2.98 (2) 2.98 (2)
Verwarming van sanitair warm water Algemeen Aangegevens belastingprofiel   L XL L XL L XL L XL
  Gematigd klimaat Energierendementsklasse waterverwarming   A+ A+ A+ A+ A+ A+ A+ A+
Verwarming Wateruitlaat gematigd klimaat 55°C Algemeen SCOP   3.27 3.27 3.27 3.27 3.26 3.26 3.26 3.26
      Seizoensefficiëntieklasse verwarming   A++ A++ A++ A++ A++ A++ A++ A++
  Wateruitlaat gematigd klimaat 35°C Algemeen SCOP   4.72 4.72 4.72 4.72 4.68 4.68 4.68 4.68
      Seizoensefficiëntieklasse verwarming   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Opmerkingen (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C)