Tabel met technische gegevens voor EBSHB-D / ERLA-DW17

EBSHB16P30DF / ERLA16D2W17 EBSHB16P50DF / ERLA16D2W17 EBSHB16P30DF / ERLA16DAW17 EBSHB16P50DF / ERLA16DAW17 EBSHB16P50DG / ERLA16D2W17 EBSHB16P30DG / ERLA16DAW17 EBSHB16P30DG / ERLA16D2W17 EBSHB16P50DG / ERLA16DAW17
Binnendeel EBSHB16P30DF EBSHB16P50DF EBSHB16P30DF EBSHB16P50DF EBSHB16P50DG EBSHB16P30DG EBSHB16P30DG EBSHB16P50DG
Totale verwarmingscapaciteit Nom. kW 16.0 (1) 16.0 (1) 16.0 (1) 16.0 (1) 16.0 16.0 16.0 16.0
Opgenomen vermogen Verwarmen Nom. kW 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1)
COP 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1)
Verwarming van sanitair warm water Algemeen Aangegevens belastingprofiel   L XL L XL XL L L XL
  Gematigd klimaat Energierendementsklasse waterverwarming   A+ A+ A+ A+ A+ A+ A+ A+
Verwarming Wateruitlaat gematigd klimaat 55°C Algemeen SCOP   3.32 3.32 3.32 3.32 3.32 3.32 3.32 3.32
      Seizoensefficiëntieklasse verwarming   A++ A++ A++ A++ A++ A++ A++ A++
  Wateruitlaat gematigd klimaat 35°C Algemeen SCOP   4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61
      Seizoensefficiëntieklasse verwarming   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Bereik van het energierendement Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F
Opmerkingen (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C)